计算溶液所需的质量、体积或浓度。
This is a demo store. No orders will be fulfilled.
| 货号 (SKU) | 包装规格 | 是否现货 | 价格 | 数量 |
|---|---|---|---|---|
| H117512-5ml |
5ml |
现货 ![]() |
| |
| H117512-25ml |
25ml |
现货 ![]() |
| |
| H117512-100ml |
100ml |
现货 ![]() |
| |
| H117512-500ml |
500ml |
现货 ![]() |
| |
| H117512-1L |
1L |
现货 ![]() |
|
| 英文别名 | .alpha.-Hexylcinnamaldehyde | Epitope ID:117426 | 2-(Phenylmethylidene)octanal | 2-Hexylcinnamaldehyde | Q412025 | EC 639-566-4 | NCGC00090930-01 | .ALPHA.-HEXYLCINNAMALDEHYDE, (2E)- | EN300-18426 | NSC406799 | NSC-406799 | alpha-Hexylcinnamic aldehyde | |
|---|---|
| 规格或纯度 | ≥92% |
| 英文名称 | α-Hexylcinnamaldehyde |
| 储存温度 | 充氩 |
| 运输条件 | 常规运输 |
| 产品介绍 |
α-己基肉桂醛可作为分析标准品,通过结合使用固相微萃取和带火焰离子化检测器气相色谱以及气相色谱-质谱联用,测定化妆品中的分析物。
α-Hexylcinnamaldehyde may be used as an analytical standard for the determination of the analyte in cosmetic products by using a combination of solid-phase microextraction and gas chromatography with flame ionization detector and gas chromatography-mass spectrometry.
|
| 纯度 | ≥92% |
| 作用机制 | Action Type | target ID | Target Name | Target Type | Target Organism | Binding Site Name | 参考文献 |
|---|
| EC号 | 202-983-3 |
|---|---|
| 分子类型 | 小分子 |
| IIUPAC Name | (2E)-2-benzylideneoctanal |
| INCHI | 1S/C15H20O/c1-2-3-4-6-11-15(13-16)12-14-9-7-5-8-10-14/h5,7-10,12-13H,2-4,6,11H2,1H3/b15-12+ |
| InChi Key | GUUHFMWKWLOQMM-NTCAYCPXSA-N |
| Smiles | CCCCCCC(=CC1=CC=CC=C1)C=O |
| Isomeric SMILES | CCCCCC/C(=C\C1=CC=CC=C1)/C=O |
| 分子量 | 216.32 |
| Beilstein号 | 7(3)1543 |
| Reaxy-Rn | 1869613 |
| Reaxys-RN link address | https://www.reaxys.com/reaxys/secured/hopinto.do?context=S&query=IDE.XRN=1869613&ln= |
| 溶解性 | 不溶于水;可溶于酒精 |
|---|---|
| 密度 | 0.96 |
| 敏感性 | 对空气敏感 |
| 折光率 | 1.55 |
| 闪点(℉) | 113 °C |
| 闪点(℃) | 113°C |
| 沸点 | 175°C/15mmHg |
| 分子量 | 216.320 g/mol |
| XLogP3 | 4.800 |
| 氢键供体数Hydrogen Bond Donor Count | 0 |
| 氢键受体数Hydrogen Bond Acceptor Count | 1 |
| 可旋转键计数Rotatable Bond Count | 7 |
| 精确质量Exact Mass | 216.151 Da |
| 单同位素质量Monoisotopic Mass | 216.151 Da |
| 拓扑极表面积Topological Polar Surface Area | 17.100 Ų |
| 重原子数Heavy Atom Count | 16 |
| 形式电荷Formal Charge | 0 |
| 复杂度Complexity | 211.000 |
| 同位素原子数Isotope Atom Count | 0 |
| 定义的原子立体中心计数Defined Atom Stereocenter Count | 0 |
| 未定义的原子立体中心计数Undefined Atom Stereocenter Count | 0 |
| 定义的键立体中心计数Defined Bond Stereocenter Count | 1 |
| 未定义的键立体中心计数Undefined Bond Stereocenter Count | 0 |
| 所有立体化学键的总数The total count of all stereochemical bonds | 1 |
| 共价键合单元计数Covalently-Bonded Unit Count | 1 |
| 象形图 | GHS07, GHS09 |
|---|---|
| 信号词 | 警告 |
| 危险声明 |
H303: 要是吞了可能有害 H314: 造成严重的皮肤灼伤和眼睛损伤 H317: 可能引起皮肤过敏反应 |
| 预防措施声明 |
P261: 避免吸入灰尘/烟雾/气体/雾/蒸汽/喷雾 P272: 被污染的工作服不允许离开工作场所 P273: 避免释放到环境中。 P280: 戴防护手套/穿防护服/戴防护眼罩/戴防护面具。 P321: 特殊处理(请参阅此标签上的...)。 P391: 收集溢出物 P302+P352: 如皮肤沾染:用水充分清洗。 P333+P313: 如发生皮肤刺激或皮疹:求医/就诊。 P362+P364: 脱掉沾污的衣服,清洗后方可重新使用。 P501: 将内容物/容器处理到。。。 |
| WGK Germany | 2 |
| RTECS | GD6560000 |
通过匹配包装上的批号来查找并下载产品的 COA,每批产品都进行了严格的验证,您可放心使用!
| 批号(Lot Number) | 证书类型 | 货号 |
|---|---|---|
| 分析证书 | H117512 | |
| 分析证书 | H117512 | |
| 分析证书 | H117512 | |
| 分析证书 | H117512 | |
| 分析证书 | H117512 | |
| 分析证书 | H117512 | |
| 分析证书 | H117512 | |
| 分析证书 | H117512 | |
| 分析证书 | H117512 | |
| 分析证书 | H117512 | |
| 分析证书 | H117512 | |
| 分析证书 | H117512 | |
| 分析证书 | H117512 | |
| 分析证书 | H117512 |
| 1. D A Basketter,E Selbie,E W Scholes,D Lees,I Kimber,P A Botham. (1993-01-01) Results with OECD recommended positive control sensitizers in the maximization, Buehler and local lymph node assays.. Food and chemical toxicology : an international journal published for the British Industrial Biological Research Association, 31 ((1)): (63-67). [PMID:8444389] |
| 2. S C Rastogi,J D Johansen,T Menné. (1996-06-01) Natural ingredients based cosmetics. Content of selected fragrance sensitizers.. Contact dermatitis, 34 ((6)): (423-426). [PMID:8879930] |
| 3. Y Nakamura,T Higaki,H Kato,F Kishida,I Nakatsuka. (1998-06-30) Comparison of sex differences in guinea-pig maximization test for detection of skin-sensitizing potential using OECD recommended positive control sensitizers.. The Journal of toxicological sciences, 23 ((2)): (105-111). [PMID:9644650] |
| 4. R J Dearman,J Hilton,P Evans,P Harvey,D A Basketter,I Kimber. (1998-08-27) Temporal stability of local lymph node assay responses to hexyl cinnamic aldehyde.. Journal of applied toxicology : JAT, 18 ((4)): (281-284). [PMID:9719428] |
| 5. Masahiro Takeyoshi,Masakuni Sawaki,Kanji Yamasaki,Ian Kimber. (2003-09-11) Assessment of statistic analysis in non-radioisotopic local lymph node assay (non-RI-LLNA) with alpha-hexylcinnamic aldehyde as an example.. Toxicology, 191 ((2-3)): (259-263). [PMID:12965128] |
| 6. Peter J Frosch,Claudia Pirker,Suresh C Rastogi,Klaus E Andersen,Magnus Bruze,Cecilia Svedman,An Goossens,Ian R White,Wolfgang Uter,Elena Giménez Arnau,Jean-Pierre Lepoittevin,Torkil Menné,Jeanne Duus Johansen. (2005-04-30) Patch testing with a new fragrance mix detects additional patients sensitive to perfumes and missed by the current fragrance mix.. Contact dermatitis, 52 ((4)): (207-215). [PMID:15859993] |
| 7. Peter J Frosch,Suresh C Rastogi,Claudia Pirker,Thomas Brinkmeier,Klaus E Andersen,Magnus Bruze,Cecilia Svedman,An Goossens,Ian R White,Wolfgang Uter,Elena Giménez Arnau,Jean-Pierre Lepoittevin,Jeanne Duus Johansen,Torkil Menne. (2005-04-30) Patch testing with a new fragrance mix - reactivity to the individual constituents and chemical detection in relevant cosmetic products.. Contact dermatitis, 52 ((4)): (216-225). [PMID:15859994] |
| 8. Masahiro Takeyoshi,Shuji Noda,Kanji Yamasaki,Ian Kimber. (2005-10-12) Advantage of using CBA/N strain mice in a non-radioisotopic modification of the local lymph node assay.. Journal of applied toxicology : JAT, 26 ((1)): (5-9). [PMID:16217858] |
| 9. Joseph R Piccotti,Stephanie A Knight,Kimberly Gillhouse,Mark S Lagattuta,Michael R Bleavins. (2006-05-18) Evaluation of an ex vivo murine local lymph node assay: multiple endpoint comparison.. Journal of applied toxicology : JAT, 26 ((4)): (333-340). [PMID:16705757] |
| 10. Darrell R Boverhof,Connie M Wiescinski,Phil Botham,David Lees,Eric Debruyne,Marina Repetto-Larsay,Gregory Ladics,Denise Hoban,Armin Gamer,Marina Remmele,Weizheng Wang-Fan,Ludwig G Ullmann,Jyotigna Mehta,Richard Billington,Michael R Woolhiser. (2008-06-17) Interlaboratory validation of 1% pluronic l92 surfactant as a suitable, aqueous vehicle for testing pesticide formulations using the murine local lymph node assay.. Toxicological sciences : an official journal of the Society of Toxicology, 105 ((1)): (79-85). [PMID:18556666] |
| 11. Zhen Liu,Junping Liu,Fei Wang,Guifeng Xu,Juan Hou,Xuying Wan,Tianbao Zhang. (2009-11-03) [Improvement of local lymph node assay for cosmetics safety evaluation].. Wei sheng yan jiu = Journal of hygiene research, 38 ((5)): (585-589). [PMID:19877522] |
| 12. M R Woolhiser,A E Munson,B J Meade. (2000-05-18) Comparison of mouse strains using the local lymph node assay.. Toxicology, 146 ((2-3)): (221-227). [PMID:10814854] |
| 13. R J Dearman,Z M Wright,D A Basketter,C A Ryan,G F Gerberick,I Kimber. (2001-05-31) The suitability of hexyl cinnamic aldehyde as a calibrant for the murine local lymph node assay.. Contact dermatitis, 44 ((6)): (357-361). [PMID:11380546] |
| 14. David A Basketter,David Sanders,Ian R Jowsey. (2007-03-09) The skin sensitization potential of resorcinol: experience with the local lymph node assay.. Contact dermatitis, 56 ((4)): (196-200). [PMID:17343618] |
| 15. David Adenuga,Michael R Woolhiser,B Bhaskar Gollapudi,Darrell R Boverhof. (2012-02-04) Differential gene expression responses distinguish contact and respiratory sensitizers and nonsensitizing irritants in the local lymph node assay.. Toxicological sciences : an official journal of the Society of Toxicology, 126 ((2)): (413-425). [PMID:22302311] |
| 16. Li Yuling, Wu Weifeng, Jian Rongchao, Ren Xiaofei, Chen Xiaole, Hong Weiqian David, Wu Min, Cai Jinglin, Lao Canyao, Xu Ximing, Sheng Zhaojun. (2023) Larvicidal, acetylcholinesterase inhibitory activities of four essential oils and their constituents against Aedes albopictus, and nanoemulsion preparation. JOURNAL OF PEST SCIENCE, 96 (3): (961-971). [10.1007/s10340-022-01555-8] |