This is a demo store. No orders will be fulfilled.

Preparation of poly(methacrylic acid-co-ethylene glycol dimethacrylate)-functionalized magnetic polydopamine nanoparticles for the extraction of six cannabinoids in wastewater followed by UHPLC-MS/MS

TALANTA [2023]
Simin Chen, Yiqi Qie, Zhendong Hua, Haoyue Zhang, Youmei Wang, Bin Di, Mengxiang Su
ABSTRACT

Phytocannabinoids and their synthetic analogs (natural and synthetic cannabinoids) are illicit drugs that are widely abused worldwide. Wastewater-based epidemiology (WBE) is an objective approach for the estimation of population-level exposure to a wide range of substances, especially drugs of abuse. However, the concentrations of cannabinoids in wastewater are extremely low (frequently at the levels of nanograms per liter), and the existing pretreatment procedures for wastewater have the disadvantages of time-consumption or low extraction recoveries. This study aimed to propose a novel poly (methacrylic acid- co -ethylene glycol dimethacrylate)-functionalized polydopamine-coated Fe 3 O 4 nanoparticle (Fe 3 O 4 @ [email protected] (MAA- co -EGDMA)) as an adsorbent, and provide a highly sensitive quantitative analytical technique for the detection of five synthetic cannabinoids (SCs: 5 F-EDMB-PINACA, FUB-APINACA, MDMB-4en-PINACA, MDMB-FUBINACA, and PB-22) and one cannabis-related human metabolite (THC-COOH) in wastewater. The magnetic adsorbents were fully characterized by transmission electron microscopy (TEM), infrared spectroscopy (IR), vibrating sample magnetometry (VSM) and X-ray photoelectron spectroscopy (XPS). Subsequently, an MSPE-UHPLC-MS/MS method was developed and validated for the determination of six trace analytes in wastewater. The validation results showed that the method has limits of quantification as low as 0.1–1.0 ng/L. Additionally, the recoveries ranged from 62.81 to 124.02%, and the relative standard deviations (RSDs) of intraday and interday precision were less than 15%. This MSPE-UHPLC-MS/MS method was successfully applied to real wastewater samples, and the whole analytical process of one sample from pretreatment to the obtained quantitative results was completed in less than 30 min. Thus, the proposed method based on Fe 3 O 4 @ [email protected] (MAA- co -EGDMA) is a convenient, rapid, sensitive and reliable method for the determination of trace psychoactive drugs in wastewater.

MATERIALS

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.